The 13/001 analog isolator has been designed for the purpose of decoupling DC signals. Its use is necessary when using electronic instruments of different brands that share one or more signals.
Technical features
- Degree of protection: IP00.
- Maximum input voltages: 0.1V / 10V / 100V / 300V / 500V.
- Input resistors: 100ohm / 10K / 100K / 300K / 500K.
- Maximum output voltage: 10V.
- Maximum output current: 5mA.
- Output resistance: 100ohm.
- Bandwidth: 200Hz.
- Linearity: ± 1%.
- Insulation voltage between input / output / power supply: 500Vac.
- Service power supply: 110 / 220Vac (switchable) - 50 / 60Hz - 2VA.
- Operating temperature: 0 / +60 ° C.
- Storage temperature: -20 / +60 ° C.
- Relative humidity: 95% without condensation.
- Maximum altitude: 1000m s.l.m.
- Connections: connector with screw connection.
- Assembly: on any type of rail.
- Settings:
- Offset.
- Output voltage.
Download
13/001 Instruction book Ed.01/2009
Instruction book in English language for the analogue isolator type 13/001